X44 Lumirror*

Features

X42, and X44 are matte films with different gloss agents blended. X42 is low gloss, and X44 high gloss.

Thickness

25,26,38,50µm

Typical properties

Properties   Unit #25
(100G)
#26
(104G)
#38
(152G)
#50
(200G)
Measurement method
Thickness MMV µm 23.5 26 38 50  
Tensile strength MD MPa 224 205 215 225 JIS C2151
TD 214 225 225 235 JIS C2151
Elongation at Break MD % 126 110 130 145 JIS C2151
TD 128 110 125 135 JIS C2151
Thermal Shrinkage
(150°C×30min)
MD % 1.3 1.5 1.2 1.2. JIS C2151
TD 0.3 0.2 0.3 0.2 JIS C2151
Specular Gloss   % 45 45 45 45 JIS Z8741

Applications

Stamping foil, labels

Attention
1. We accept no responsibility for results obtained by the application of the information indicated and for the safety and suitability of the products, by itself or in combination with other products. Users are advised to perform their own tests to determine the safety and suitability of such product and product combinationaccording to each of its purposes.
2. Refer to our MSDS (Material Safety Data Sheet) before use.
3. The publication is not to be taken as a license to operate under, or as a recommendation to infringe any patents.
  • Back
  • Print Friendly Page

PAGE TOP

  • Terms of use
  • Privacy Policy
  • Site map

X44 Lumirror*

Polyester Film Lumirror*

Features

X42, X43, and X44 are matte films with different gloss agents blended. X42 is low gloss, x43 medium gloss, and X44 high gloss.

Thickness

25,26,38,50µm

Typical properties

Properties   Unit #25
(100G)
#26
(104G)
#38
(152G)
#50
(200G)
Measurement method
Thickness MMV µm 23.5 26 38 50  
Tensile strength MD MPa 224 205 215 225 JIS C2151
TD 214 225 225 235 JIS C2151
Elongation at Break MD % 126 110 130 145 JIS C2151
TD 128 110 125 135 JIS C2151
Thermal Shrinkage
(150°C×30min)
MD % 1.3 1.5 1.2 1.2. JIS C2151
TD 0.3 0.2 0.3 0.2 JIS C2151
Specular Gloss   % 45 45 45 45 JIS Z8741

Applications

Stamping foil, labels

Attention
1. We accept no responsibility for results obtained by the application of the information indicated and for the safety and suitability of the products, by itself or in combination with other products. Users are advised to perform their own tests to determine the safety and suitability of such product and product combinationaccording to each of its purposes.
2. Refer to our MSDS (Material Safety Data Sheet) before use.
3. The publication is not to be taken as a license to operate under, or as a recommendation to infringe any patents.