S105 Lumirror*

Features

S105 is a variant of S10, with corona treatment on one side.

Thickness

23,38,50,75µm

Typical properties

Properties Unit #25
(92G)
#38
(150G)
#50
(200G)
#75
(300G)
Measurement method
Thickness MMV µm 23 38 50 75 JIS C2151
Tensile strength MD MPa 233 238 236 218 JIS C2151
TD 235 234 229 226 JIS C2151
Elongation at Break MD % 175 184 195 167 JIS C2151
TD 167 176 181 157 JIS C2151
Thermal Shrinkage
(150°C×30min)
MD % 1.2 1.2 1.1 1.1 JIS C2151
TD 0.0 -0.1 0.2 0.3 JIS C2151
Breakdown Voltage   kV 7.4 10.0 11.9 15.0 JIS C2151
Surface wetting tension   mN/m 53 54 54 53 JIS K6768

Applications

Labels, adhesive tapes, lamination

Attention
1. We accept no responsibility for results obtained by the application of the information indicated and for the safety and suitability of the products, by itself or in combination with other products. Users are advised to perform their own tests to determine the safety and suitability of such product and product combinationaccording to each of its purposes.
2. Refer to our MSDS (Material Safety Data Sheet) before use.
3. The publication is not to be taken as a license to operate under, or as a recommendation to infringe any patents.
  • Back
  • Print Friendly Page

PAGE TOP

  • Terms of use
  • Privacy Policy
  • Site map

S105 Lumirror*

Polyester Film Lumirror*

Features

S105 is a variant of S10, with corona treatment on one side.

Thickness

23,38,50,75µm

Typical properties

Properties Unit #25
(92G)
#38
(150G)
#50
(200G)
#75
(300G)
Measurement method
Thickness MMV µm 23 38 50 75 JIS C2151
Tensile strength MD MPa 233 238 236 218 JIS C2151
TD 235 234 229 226 JIS C2151
Elongation at Break MD % 175 184 195 167 JIS C2151
TD 167 176 181 157 JIS C2151
Thermal Shrinkage
(150°C×30min)
MD % 1.2 1.2 1.1 1.1 JIS C2151
TD 0.0 -0.1 0.2 0.3 JIS C2151
Breakdown Voltage   kV 7.4 10.0 11.9 15.0 JIS C2151
Surface wetting tension   mN/m 53 54 54 53 JIS K6768

Applications

Labels, adhesive tapes, lamination

Attention
1. We accept no responsibility for results obtained by the application of the information indicated and for the safety and suitability of the products, by itself or in combination with other products. Users are advised to perform their own tests to determine the safety and suitability of such product and product combinationaccording to each of its purposes.
2. Refer to our MSDS (Material Safety Data Sheet) before use.
3. The publication is not to be taken as a license to operate under, or as a recommendation to infringe any patents.

Print